矿用电缆挂钩安装需要:
矿用电缆挂钩安装需要:
The installation of mine cable hook requires:
1) 根据电缆型号及外径的大小选择适合的电缆挂钩,每1.2m~1.8m(也可以以电缆不下垂为限)为一个悬挂单位,每一单元根据悬挂一个或多个电缆挂钩。
1) Select the appropriate cable hook according to the cable model and
outer diameter. Every 1.2m ~ 1.8m (or the cable does not sag) is a
suspension unit, and one or more cable hooks are suspended for each
unit.
2) 悬挂时,先将专门螺栓或其它悬挂件穿孔将挂钩固定在井壁上,挂钩固定时,弧形钩呈垂直下垂状。如多根电缆悬挂需采用一组挂钩两两串联悬挂。施工人员在地面上先将挂钩两两串联,再依前法固定。
2) When hanging, special bolts or other hanging parts shall be
perforated first to fix the hook on the shaft wall. When the hook is
fixed, the arc hook is in a vertical drooping shape. If multiple cables
are suspended, a set of hooks shall be used for two in series
suspension. The construction personnel first connect the hooks in series
on the ground, and then fix them according to the previous method.
3) 两个挂钩串联时,先将一个挂钩的挂孔对准另一个挂钩的挂杆,用力按入,使挂杆完全进入挂孔,然后手持弧形钩旋转,使两挂钩直杆段成180℃。
3) When two hooks are connected in series, first align the hanging hole
of one hook with the hanging rod of the other hook, press it firmly to
make the hanging rod fully enter the hanging hole, and then rotate with
the arc hook to make the straight rod section of the two hooks 180 ℃.
4) 确认电缆整体进入弧形钩后,施工人员才可以放开电缆。
4) After confirming that the cable enters the arc hook as a whole, the construction personnel can release the cable